Watts
(Capacity)
2930 2720 2430 2080
Watts (Power) 595 695 818 957
5
Amps 2.03 2.10 2.20 2.34
Watts
(Capacity)
3210 2990 2670 2280
Watts (Power) 610 705 829 973
7.2
Amps 2.02 2.10 2.21 2.36
Watts
(Capacity)
3600 3350 2990 2560
Watts (Power) 633 720 842 991
10
Amps 2.02 2.11 2.23 2.38
Watts
(Capacity)
4400 4080 3650 3130
Watts (Power) 683 752 867 1020
15
Amps 2.00 2.11 2.25 2.43
COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW
C1 2.115276E+03 3.969978E+02 2.083010E+00
C2 1.110061E+02 2.219743E+01 -1.315190E-02
C3 3.149417E+01 1.136716E-01 -6.455860E-03
C4 2.656230E+00 4.139570E-01 -4.190000E-05
C5 1.288696E-01 -9.138685E-01 3.840230E-04
C6 -9.164568E-01 2.251823E-01 1.641760E-04
C7 1.287802E-02 5.496900E-03 0.000000E+00
C8 -2.394002E-02 -1.087205E-02 0.000000E+00
C9 -1.173955E-02 1.165829E-02 0.000000E+00
C10 4.424094E-03 -1.383704E-03 0.000000E+00
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3